045401.5NR Littelfuse 1.5 A time-lag (Slo-Blo) NANO2 Fuse
045401.5NR Littelfuse 1.5 A time-lag (Slo-Blo) NANO2 Fuse

045401.5NR Littelfuse 1.5 A time-lag (Slo-Blo) NANO2 Fuse

Share
p045401.5NR: 1.5 A time-lag (Slo-Blo) Littelfuse 454 Series surface-mount fuse rated for 125 VAC/VDC./p
    • Product Details
    • Download

    045401.5NR Littelfuse 1.5 A time-lag (Slo-Blo) NANO2 Fuse

    For circuits requiring a 1.5 A protection point, Littelfuse 045401.5NR provides time-lag (Slo-Blo) overcurrent protection in the 2410 / 6125 NANO2 platform. The rating is suited to power supplies with startup surge, provided the startup waveform and ambient rerating are checked against the latest curves. Its 50 A @ 125 VAC/VDC; 300 A @ 32 VDC interrupting specification supports fault-current coordination when the applied voltage remains within 125 VAC/VDC.

    Best fit: white goods and industrial electronics using a 1.5 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 1.5 A time-lag (Slo-Blo) protection for circuits up to 125 VAC/VDC
    • 0.0930 Ω nominal cold resistance for loss and voltage-drop estimation
    • 3.65 A²s nominal melting I²t for pulse-withstand and coordination review
    • 50 A @ 125 VAC/VDC; 300 A @ 32 VDC interrupting capability
    • UL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 454 Series
    Part number045401.5NR
    Fuse characteristictime-lag (Slo-Blo)
    Rated current1.5 A
    Voltage rating125 VAC/VDC
    Interrupting rating50 A @ 125 VAC/VDC; 300 A @ 32 VDC
    Nominal cold resistance0.0930 Ω
    Nominal melting I²t3.65 A²s
    Package2410 / 6125 NANO2
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Best-Fit Applications

    • white goods and industrial electronics
    • power supplies with startup surge
    • storage and server equipment

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 1.5 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 50 A @ 125 VAC/VDC; 300 A @ 32 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 2410 / 6125 NANO2 package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 045401.5NR within the 454 Series?
    Its defining electrical point is 1.5 A with a 125 VAC/VDC maximum rating and time-lag (Slo-Blo) opening behavior.

    Can 045401.5NR be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 045401.5NR intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 2410 / 6125 NANO2 construction.

    Ordering and Packaging

    Packaging: 1,000-piece MR or 5,000-piece NR tape-and-reel; 454 is supplied as RoHS/halogen-free without an L suffix.

    Ordering reference: start with 045401.5NR and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products