0456040.DR Littelfuse 40 A very fast-acting NANO2 Fuse
0456040.DR Littelfuse 40 A very fast-acting NANO2 Fuse

0456040.DR Littelfuse 40 A very fast-acting NANO2 Fuse

Share
40 A very fast-acting SMD fuse from the Littelfuse 456 Series; model 0456040.DR.
    • Product Details
    • Download

    0456040.DR Littelfuse 40 A very fast-acting NANO2 Fuse

    For circuits requiring a 40 A protection point, Littelfuse 0456040.DR provides very fast-acting overcurrent protection in the 4012 NANO2 high-current SMD platform. The rating is suited to telecom power equipment, provided the startup waveform and ambient rerating are checked against the latest curves. Its 600 A @ 60 VDC interrupting specification supports fault-current coordination when the applied voltage remains within 60 VDC.

    Best fit: telecom power equipment using a 40 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 40 A very fast-acting protection for circuits up to 60 VDC
    • 0.00105 Ω nominal cold resistance for loss and voltage-drop estimation
    • 191 A²s nominal melting I²t for pulse-withstand and coordination review
    • 600 A @ 60 VDC interrupting capability
    • UL Recognized, RoHS compliant and lead-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 456 Series
    Part number0456040.DR
    Fuse characteristicvery fast-acting
    Rated current40 A
    Voltage rating60 VDC
    Interrupting rating600 A @ 60 VDC
    Nominal cold resistance0.00105 Ω
    Nominal melting I²t191 A²s
    Package4012 NANO2 high-current SMD
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, RoHS compliant and lead-free

    Best-Fit Applications

    • telecom power equipment
    • high-current server rails
    • battery and power-distribution boards

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 40 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 600 A @ 60 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 4012 NANO2 high-current SMD package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0456040.DR within the 456 Series?
    Its defining electrical point is 40 A with a 60 VDC maximum rating and very fast-acting opening behavior.

    Can 0456040.DR be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0456040.DR intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 4012 NANO2 high-current SMD construction.

    Ordering and Packaging

    Packaging: Specify the exact tape-and-reel ordering suffix when requesting stock or a quotation.

    Ordering reference: start with 0456040.DR and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.