0458007.DR: 7 A inrush-withstand Littelfuse 458 Series surface-mount fuse rated for 63 VDC / 32 VAC.
    • Product Details
    • Download

    0458007.DR 458 Series 7 A PCB Fuse by Littelfuse

    The 0458007.DR fuse targets 7 A rails that need inrush-withstand behavior without moving to a cartridge-style footprint. Its 50 A at the applicable AC/DC rating interrupting specification supports fault-current coordination when the applied voltage remains within 63 VDC / 32 VAC. The -55 °C to +125 °C operating range broadens its use across compact power-conversion and control assemblies.

    Best fit: compact DC/DC converters using a 7 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 7 A inrush-withstand protection for circuits up to 63 VDC / 32 VAC
    • 0.0175 Ω nominal cold resistance for loss and voltage-drop estimation
    • 20.48 A²s nominal melting I²t for pulse-withstand and coordination review
    • 50 A at the applicable AC/DC rating interrupting capability
    • UL Recognized, RoHS compliant, halogen-free and lead-free assembly compatible

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 458 Series
    Part number0458007.DR
    Fuse characteristicinrush-withstand
    Rated current7 A
    Voltage rating63 VDC / 32 VAC
    Interrupting rating50 A at the applicable AC/DC rating
    Nominal cold resistance0.0175 Ω
    Nominal melting I²t20.48 A²s
    Package1206 / 3216 NANO2 wire-in-air
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, RoHS compliant, halogen-free and lead-free assembly compatible

    Best-Fit Applications

    • compact DC/DC converters
    • battery packs and portable electronics
    • network and telecom equipment

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 7 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 50 A at the applicable AC/DC rating at the applied voltage. Use the manufacturer-recommended land pattern for the 1206 / 3216 NANO2 wire-in-air package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0458007.DR within the 458 Series?
    Its defining electrical point is 7 A with a 63 VDC / 32 VAC maximum rating and inrush-withstand opening behavior.

    Can 0458007.DR be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0458007.DR intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 1206 / 3216 NANO2 wire-in-air construction.

    Ordering and Packaging

    Packaging: 1,500 pieces on 8 mm tape-and-reel; quantity/packaging code DR.

    Ordering reference: start with 0458007.DR and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.