048501.5DR 485 Series 1.5 A PCB Fuse by Littelfuse
048501.5DR 485 Series 1.5 A PCB Fuse by Littelfuse

048501.5DR 485 Series 1.5 A PCB Fuse by Littelfuse

Share
Compact 12.1 × 4.5 mm NANO2 high-voltage SMD protection at 1.5 A, Littelfuse 048501.5DR, fast-acting.
    • Product Details
    • Download

    048501.5DR 485 Series 1.5 A PCB Fuse by Littelfuse

    The 048501.5DR fuse targets 1.5 A rails that need fast-acting behavior without moving to a cartridge-style footprint. Its 100 A @ 600 VDC; 100 A @ 250 VAC interrupting specification supports fault-current coordination when the applied voltage remains within 600 VDC / 250 VAC. The -55 °C to +125 °C operating range broadens its use across compact power-conversion and control assemblies.

    Best fit: 380 VDC data-center power using a 1.5 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 1.5 A fast-acting protection for circuits up to 600 VDC / 250 VAC
    • 0.123 Ω nominal cold resistance for loss and voltage-drop estimation
    • 0.3917 A²s nominal melting I²t for pulse-withstand and coordination review
    • 100 A @ 600 VDC; 100 A @ 250 VAC interrupting capability
    • UL Recognized, CSA Certified, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 485 Series
    Part number048501.5DR
    Fuse characteristicfast-acting
    Rated current1.5 A
    Voltage rating600 VDC / 250 VAC
    Interrupting rating100 A @ 600 VDC; 100 A @ 250 VAC
    Nominal cold resistance0.123 Ω
    Nominal melting I²t0.3917 A²s
    Package12.1 × 4.5 mm NANO2 high-voltage SMD
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, CSA Certified, RoHS compliant and halogen-free

    Best-Fit Applications

    • 380 VDC data-center power
    • three-phase UPS power supplies
    • high-voltage lighting and telecom equipment

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 1.5 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 100 A @ 600 VDC; 100 A @ 250 VAC at the applied voltage. Use the manufacturer-recommended land pattern for the 12.1 × 4.5 mm NANO2 high-voltage SMD package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 048501.5DR within the 485 Series?
    Its defining electrical point is 1.5 A with a 600 VDC / 250 VAC maximum rating and fast-acting opening behavior.

    Can 048501.5DR be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 048501.5DR intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 12.1 × 4.5 mm NANO2 high-voltage SMD construction.

    Ordering and Packaging

    Packaging: 1,500 pieces on tape-and-reel; quantity/packaging code DR.

    Ordering reference: start with 048501.5DR and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.

    Shenzhen Gaorunxin Technology Co., Ltd