| Part number | MDL-1-R |
| Typical voltage drop | 0.995 V |
| Body | Glass tube, 1/4 x 1-1/4 in (6.4 x 31.7 mm) |
| AC interrupting rating | 35 A at 250 Vac; 10,000 A at 125 Vac |
| Design standard | UL 248-14 |
| Element | single element |
| Typical DC cold resistance | 0.273 Ω |
| Voltage rating | 250 Vac |
| Rated current | 1 A |
| End caps | nickel-plated brass |
| Typical melting I2t | 11.498 A²s |
Time-delay exists because motors, transformers and solenoids all draw far more than their rated current for a moment. A fuse sized for the running current would open on every start; a fuse sized for the start current would never protect the winding. The delay curve lets one part do both jobs.
The typical cold resistance is 0.273 Ω, which is what the circuit sees before the element warms. Melting takes 11.498 A²s, so a fault has to deliver that much energy before the element even starts to go. At rated current the drop across it is 0.995 V. Those are the figures that decide whether this part fits a circuit, and none of them appears on the label.
MDL is the family and 1 is the ampere rating, 1 A. The trailing -R marks the RoHS version; a packaging prefix such as BK- or BK1- may be added in front, which alters the quantity per box only.
In this band the cold resistance is already low enough that the voltage drop is a fraction of a volt at rated current, so it does not distort the load. The I2t is still small, which means the part will not survive a hard capacitive inrush without help.
The step below is MDL-3/4-R at 750 mA, the step above is MDL-1-1/4-R at 1.25 A. Between the three the body, the end caps and the breaking capacity are identical; only the element changes, so the choice is the load current and nothing else.
UL Listed 1/16-8 A (Guide JDYX, File E19180); UL Recognized 9-30 A (JDYX2); CSA 1/16-8 A (1422-01), 9-30 A (1422-30); CE.
For a submittal pack, match the certificate to the rating on the order line. Eaton publishes the recognised range alongside each standard, and the boundary between Listed and Recognised often falls inside the family rather than at its end.
UL Listed 1/16-8 A (Guide JDYX, File E19180); UL Recognized 9-30 A (JDYX2); CSA 1/16-8 A (1422-01), 9-30 A (1422-30); CE.
Where the equipment ships into several markets, check each approval separately - the European and North American marks on this family do not always cover the same current range, and the gap is usually at the top of the range.
MDL and AGC share the same 1/4 x 1-1/4 in body and the same end caps. The only difference is the element, so a fast-acting part will physically drop into a socket that expects a time-delay one. Check the letter code on the cap, not the size of the fuse.
This rating is normally held against a specific circuit rather than as a general spare. If it is being replaced outside a planned maintenance, confirm what the circuit actually draws before fitting another 1 A part.
What does the voltage drop figure mean in practice?
It is the voltage lost across the fuse at rated current, which is the same as saying it is the power the fuse dissipates divided by the current. On a low-voltage rail a large drop steals headroom from the load.
How tight should the holder clip be?
Tight enough that the fuse cannot be shaken out, loose enough that it can be pulled by hand. A clip that has lost its spring is a heat source, and the fuse gets blamed for it.
Why does the table list several breaking capacities?
Because the fuse is asked to interrupt different currents at different voltages. The 250 Vac figure is usually the smallest and the 32 V figure the largest, since a low voltage is much easier to break than a high one.
Design note: the ratings above are Technical Data 2004. Verify the exact rating, the voltage at which the breaking capacity applies, and the certificate for this current before release.