10 A very fast-acting Surface-Mount Fuse – Littelfuse 0453010.NR
10 A very fast-acting Surface-Mount Fuse – Littelfuse 0453010.NR

10 A very fast-acting Surface-Mount Fuse – Littelfuse 0453010.NR

Share
0453010.NR: 10 A very fast-acting Littelfuse 453 Series surface-mount fuse rated for 125 VAC/VDC.
    • Product Details
    • Download

    10 A very fast-acting Surface-Mount Fuse – Littelfuse 0453010.NR

    Littelfuse 0453010.NR is specified at 10 A and 125 VAC/VDC, giving designers a compact very fast-acting fuse for board-level protection. The -55 °C to +125 °C operating range broadens its use across compact power-conversion and control assemblies. A nominal cold resistance of 0.0056 Ω helps quantify conduction loss, while the 26.46 A²s nominal melting I²t supports pulse-energy review.

    Best fit: networking and telecom equipment using a 10 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 10 A very fast-acting protection for circuits up to 125 VAC/VDC
    • 0.0056 Ω nominal cold resistance for loss and voltage-drop estimation
    • 26.46 A²s nominal melting I²t for pulse-withstand and coordination review
    • 35 A @ 125 VAC; 50 A @ 125 VDC; 400 A @ 32 VDC interrupting capability
    • UL/CSA approvals by rating, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 453 Series
    Part number0453010.NR
    Fuse characteristicvery fast-acting
    Rated current10 A
    Voltage rating125 VAC/VDC
    Interrupting rating35 A @ 125 VAC; 50 A @ 125 VDC; 400 A @ 32 VDC
    Nominal cold resistance0.0056 Ω
    Nominal melting I²t26.46 A²s
    Package2410 / 6125 NANO2
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL/CSA approvals by rating, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Best-Fit Applications

    • networking and telecom equipment
    • secondary-side power rails
    • notebook and display electronics

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 10 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 35 A @ 125 VAC; 50 A @ 125 VDC; 400 A @ 32 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 2410 / 6125 NANO2 package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0453010.NR within the 453 Series?
    Its defining electrical point is 10 A with a 125 VAC/VDC maximum rating and very fast-acting opening behavior.

    Can 0453010.NR be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0453010.NR intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 2410 / 6125 NANO2 construction.

    Ordering and Packaging

    Packaging: 1,000-piece MR or 5,000-piece NR tape-and-reel; the 453 Series does not use an L suffix.

    Ordering reference: start with 0453010.NR and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products