
The Eaton Bussmann 170M2057 is a high speed fuse rated 2000V at 215A. It is used for DC links and semiconductor stacks that need sub-millisecond clearing.
| Model | Current | Voltage | Class |
|---|---|---|---|
| 170M5678 | — | 1000VAC | — |
| 170M2714 | — | — | — |
| 170M1367 | — | — | — |
| 170M6689 | — | — | — |
| 170M3193 | — | 1000V | — |
| 170M1309 | 16A | 690V (IEC) | aR |
| 170M1410 | 20A | 700V | — |
| 170M4802 | 20A | 1000V (IEC) | Class aR |
| 170M1560 | 20A | 690V | — |
| 170M1411 | 25A | 690V | — |
| 170M1362 | 32A | 690V | — |
| 170M1563 | 40A | 690V | — |
| 170M2050 | 50A | 2000V | — |
| 170M1564 | 50A | 690V | — |
| 170M3921 | 63A | 1000V | — |
| 170M1315 | 63A | 690V (IEC) | aR |
| 170M1365 | 63A | 690V (IEC) | aR |
| 170M3922 | 80A | 1000V | — |
| 170M1366 | 80A | 690V | — |
| 170M1566 | 80A | 690V | — |
| 170M0166 | 80A | 660V | — |
| 170M2700 | 100A | 700V | — |
| 170M1317 | 100A | 690V (IEC) | aR |
| 170M3662 | 100A | 690V | — |
| 170M3492†† | 125A | 1250V | — |
| 170M1468 | 125A | 700V | — |
| 170M2701 | 125A | 690V | — |
| 170M1318 | 125A | 690V (IEC) | aR |
| 170M1418 | 125A | 690V (IEC) | Class aR |
| 170M1368 | 125A | 700V | — |
| 170M1468 | 125A | 690V(IEC) | aR |
| 170M6094 | 130A | 7200V | — |
| 170M4846 | 140A | 4500V | — |
| 170M3925 | 160A | 1000V | — |
| 170M1569 | 160A | 690V | — |
| 170M4812 | 160A | 1000V (IEC) | Class aR |
| 170M2666 | 160A | 690V | Class aR |
| 170M3143 | 160A | 1250Vac | — |
| 170M3243 | 160A | 1000V | — |
| 170M2702 | 160A | 690V | — |
| 170M7102 | 200A | 1000V | — |
| 170M3926 | 200A | 1000V | — |
| 170M4813 | 200A | 1000V | — |
| 170M3015 | 200A | 690V (IEC) | aR |
| 170M2667 | 200A | 690VAC | — |
| 170M1370 | 200A | 690V (IEC) | aR |
| 170M2667 | 200A | 690V | Class aR |
| 170M3815 | 200A | 690V | — |
| 170M2057 | 215A | 2000V | — |
| 170M7103 | 225A | 1000V | — |
| 170M5922 | 250A | 1000V | — |
| 170M3927 | 250A | 1000V | — |
| 170M3972 | 250A | 1000V | — |
| 170M1421 | 250A | 690V | — |
| 170M5138 | 250A | 1250V (IEC) | Class aR |
| 170M3016 | 250A | 690V (IEC) | aR |
| 170M1321 | 250A | 690V (IEC) | aR |
| 170M1421 | 250A | 690V (IEC) | aR |
| 170M3816 | 250A | 690V | — |
| 170M3016 | 250A | 690V | — |
| 170M3816D | 250A | 690V | — |
| 170M1321 | 250A | 690V | — |
| 170M3928 | 315A | 1000V | — |
| 170M1572 | 315A | 690V | — |
| 170M4410 | 315A | 690V | — |
| 170M8629 | 315A | 1000V | — |
| 170M3267 | 315A | 690V | — |
| 170M4460 | 315A | 690V | — |
| 170M3817D | 315A | 700V | — |
| 170M5140 | 315A | 1250V (IEC) | Class aR |
| 170M1322 | 315A | 690V (IEC) | aR |
| 170M1422 | 315A | 690V (IEC) | aR |
| 170M2620 | 315A | 690V (IEC) | aR |
| 170M1372 | 315A | 690V (IEC) | aR |
| 170M1372 | 315A | 700V | — |
| 170M3973 | 315A | 690VAC | — |
| 170M2042 | 315A | 2000V | — |
| 170M1322 | 315A | 690V | — |
| 170M1372 | 315A | 690V | — |
| 170M6589 | 350A | 1250VAC | — |
| 170M3929 | 350A | 1000V | — |
| 170M3974 | 350A | 1000V | — |
| 170M4461 | 350A | 690V | — |
| 170M3018 | 350A | 690V | — |
| 170M3018 | 350A | 690V (IEC) | aR |
| 170M3990 | 350A | 1000V | Class aR |
| 170M3930 | 400A | 1000V | — |
| 170M3975 | 400A | 1000V | — |
| 170M4462 | 400A | 690V | — |
| 170M3469 | 400A | 690V | — |
| 170M5984 | 400A | 1000V | — |
| 170M5808D | 400A | 690V | aR |
| 170M5258_ | 400A | 690V | — |
| 170M4199 | 400A | 1250V | — |
| 170M5142 | 400A | 1250V (IEC) | Class aR |
| 170M5108 | 400A | 690V (IEC) | Class aR |
| 170M5018 | 400A | 690V | — |
| 170M5008_ | 400A | 690V | — |
| 170M5008 | 400A | 690V (IEC) | aR |
| 170M3019 | 400A | 690V (IEC) | aR |
| 170M2671 | 400A | 690V (IEC) | Class aR |
| 170M2621 | 400A | 690V (IEC) | aR |
| 170M3819D | 400A | 690V | — |
| 170M5458 | 400A | 690V | — |
| 170M3819D | 400A | 690V | — |
| 170M4863D | 450A | 690V | — |
| 170M5809D | 450A | 690V | — |
| 170M3270 | 450A | 690V | — |
| 170M5143 | 450A | 1250V (IEC) | Class aR |
| 170M5059 | 450A | 690V | Class aR |
| 170M3020 | 450A | 690V (IEC) | aR |
| 170M5927 | 500A | 1000V | — |
| 170M6408 | 500A | 690V | — |
| 170M5810 | 500A | 690V | aR |
| 170M5810D | 500A | 690V | aR |
| 170M5060 | 500A | 690V (IEC) | Class aR |
| 170M6408 | 500A | 690V (IEC) | Class aR |
| 170M6458 | 500A | 690V (IEC) | Class aR |
| 170M3021 | 500A | 690V (IEC) | aR |
| 170M6008 | 500A | 690V (IEC) | Class aR |
| 170M3271 | 500A | 690V | — |
| 170M4614 | 500A | 690V | — |
| 170M3021 | 500A | 690V | — |
| 170M5410 | 500A | 690VAC | — |
| 170M5211 | 550A | 690V | — |
| 170M5811D | 550A | 690V (IEC) | Class aR |
| 170M3122 | 550A | 690V | — |
| 170M5145 | 550A | 1250V (IEC) | Class aR |
| 170M5111 | 550A | 690V | — |
| 170M5061 | 550A | 690V (IEC) | Class aR |
| 170M6009 | 550A | 690V (IEC) | aR |
| 170M3022 | 550A | 690V | — |
| 170M5145 | 550A | 1250V | — |
| 170M3122 | 550A | 690V | — |
| 170M2045 | 600A | 2000V | — |
| 170M5889 | 630A | 690V | — |
| 170M6460 | 630A | 690V | — |
| 170M6260 | 630A | 690V | — |
| 170M5112 | 630A | 690V | — |
| 170M4197 | 630A | 1100V | — |
| 170M6810D | 630A | 690V | — |
| 170M4016 | 630A | 690V | — |
| 170M5812D | 630A | 690V (IEC) | Class aR |
| 170M5812D | 630A | 690V | aR |
| 170M5462 | 630A | 690V (IEC) | Class aR |
| 170M6410_ | 630A | 690V | — |
| 170M5146 | 630A | 1250V (IEC) | Class aR |
| 170M5062 | 630A | 690V (IEC) | Class aR |
| 170M6010 | 630A | 690V (IEC) | aR |
| 170M5146 | 630A | 690V (IEC) | aR |
251 models in the 170M family; first 150 shown, sorted by rated current.
DC links and semiconductor stacks that need sub-millisecond clearing.
Match the fuse I²t to the device it protects; a larger fuse protects the cable but not the semiconductor.
For DC circuits confirm the time constant, since clearing time depends on the circuit L/R.
What is the 170M2057 rated for?
It is rated 2000V at 215A.
What class is this fuse?
The class is not stated on the manufacturer page; confirm on the datasheet before ordering.
Can I replace it with a different class?
No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.
What does the interrupting rating mean?
It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.
How do I verify the part number?
Order by the full catalog number 170M2057; suffixes change the terminal, voltage or package.
Where can I find the datasheet?
The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.
Source: manufacturer catalog page for 170M2057. Verify ratings against the current datasheet before ordering.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd