46208000000 462 Series 800 mA PCB Fuse by Littelfuse
46208000000 462 Series 800 mA PCB Fuse by Littelfuse

46208000000 462 Series 800 mA PCB Fuse by Littelfuse

Share
p800 mA time-lag SMD fuse from the Littelfuse 462 Series; model 46208000000./p
    • Product Details
    • Download

    46208000000 462 Series 800 mA PCB Fuse by Littelfuse

    The 46208000000 fuse targets 800 mA rails that need time-lag behavior without moving to a cartridge-style footprint. Its 100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC interrupting specification supports fault-current coordination when the applied voltage remains within 250 VAC/VDC IEC; 350 VAC/VDC UL. The -40 °C to +85 °C operating range broadens its use across compact power-conversion and control assemblies.

    Best fit: lighting ballasts using a 800 mA protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 800 mA time-lag protection for circuits up to 250 VAC/VDC IEC; 350 VAC/VDC UL
    • 0.13 Ω nominal cold resistance for loss and voltage-drop estimation
    • 1.4 A²s nominal melting I²t for pulse-withstand and coordination review
    • 100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC interrupting capability
    • UL Recognized, IEC 60127-4 UMF approvals, RoHS compliant, halogen-free and lead-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 462 Series
    Part number46208000000
    Fuse characteristictime-lag
    Rated current800 mA
    Voltage rating250 VAC/VDC IEC; 350 VAC/VDC UL
    Interrupting rating100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC
    Nominal cold resistance0.13 Ω
    Nominal melting I²t1.4 A²s
    Package10.5 × 4.5 mm NANO2 UMF
    Operating temperature-40 °C to +85 °C
    Agency / environmentalUL Recognized, IEC 60127-4 UMF approvals, RoHS compliant, halogen-free and lead-free

    Best-Fit Applications

    • lighting ballasts
    • AC/DC adapter primary protection
    • high-voltage DC distribution

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 800 mA rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 10.5 × 4.5 mm NANO2 UMF package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 46208000000 within the 462 Series?
    Its defining electrical point is 800 mA with a 250 VAC/VDC IEC; 350 VAC/VDC UL maximum rating and time-lag opening behavior.

    Can 46208000000 be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 46208000000 intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 10.5 × 4.5 mm NANO2 UMF construction.

    Ordering and Packaging

    Packaging: 1,500 pieces on 16 mm tape-and-reel; packaging code 0.

    Ordering reference: start with 46208000000 and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.