46212500000 462 Series 2.5 A PCB Fuse by Littelfuse
46212500000 462 Series 2.5 A PCB Fuse by Littelfuse

46212500000 462 Series 2.5 A PCB Fuse by Littelfuse

Share
46212500000: 2.5 A time-lag Littelfuse 462 Series surface-mount fuse rated for 250 VAC/VDC IEC; 350 VAC/VDC UL.
    • Product Details
    • Download

    46212500000 462 Series 2.5 A PCB Fuse by Littelfuse

    The 46212500000 fuse targets 2.5 A rails that need time-lag behavior without moving to a cartridge-style footprint. Its 100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC interrupting specification supports fault-current coordination when the applied voltage remains within 250 VAC/VDC IEC; 350 VAC/VDC UL. The -40 °C to +85 °C operating range broadens its use across compact power-conversion and control assemblies.

    Best fit: high-voltage DC distribution using a 2.5 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 2.5 A time-lag protection for circuits up to 250 VAC/VDC IEC; 350 VAC/VDC UL
    • 0.0278 Ω nominal cold resistance for loss and voltage-drop estimation
    • 8.0 A²s nominal melting I²t for pulse-withstand and coordination review
    • 100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC interrupting capability
    • UL Recognized, IEC 60127-4 UMF approvals, RoHS compliant, halogen-free and lead-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 462 Series
    Part number46212500000
    Fuse characteristictime-lag
    Rated current2.5 A
    Voltage rating250 VAC/VDC IEC; 350 VAC/VDC UL
    Interrupting rating100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC
    Nominal cold resistance0.0278 Ω
    Nominal melting I²t8.0 A²s
    Package10.5 × 4.5 mm NANO2 UMF
    Operating temperature-40 °C to +85 °C
    Agency / environmentalUL Recognized, IEC 60127-4 UMF approvals, RoHS compliant, halogen-free and lead-free

    Best-Fit Applications

    • high-voltage DC distribution
    • lighting ballasts
    • AC/DC adapter primary protection

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 2.5 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 10.5 × 4.5 mm NANO2 UMF package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 46212500000 within the 462 Series?
    Its defining electrical point is 2.5 A with a 250 VAC/VDC IEC; 350 VAC/VDC UL maximum rating and time-lag opening behavior.

    Can 46212500000 be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 46212500000 intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 10.5 × 4.5 mm NANO2 UMF construction.

    Ordering and Packaging

    Packaging: 1,500 pieces on 16 mm tape-and-reel; packaging code 0.

    Ordering reference: start with 46212500000 and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message