pEaton 1025FA5-R: 5 A fast-acting SMD fuse, 10.29 x 2.77 mm (4010 imperial / 1025 metric), 250 Vac. Ordering code TR2/1025FA5-R./p
    • Product Details
    • Download

    5 A 250 Vac Fast-Blow Ceramic Fuse - Eaton 1025FA5-R

    5 A at 250 Vac - fast-acting, 10.29 x 2.77 mm surface-mount, EIA/IS-722.
    Supplied as TR2/1025FA5-R - 2,500 pieces on 24 mm tape-and-reel, one 13 inch (330 mm) reel.

    Key Parameters

    Part number1025FA5-R
    Ordering codeTR2/1025FA5-R
    Packaging2,500 pcs on 24 mm tape-and-reel, 13 in (330 mm) reel, EIA-481
    Package10.29 x 2.77 mm (4010 imperial / 1025 metric)
    Agency approvalUL Recognition, Guide JDYX2, File E19180 (250 mA - 15 A); CSA component acceptance
    Typical cold resistance0.0195 Ω
    Rated current5 A
    Design standardEIA/IS-722
    Typical voltage drop180 mV
    Voltage rating250 Vac
    Interrupting rating50 A AC; 50 A 125 Vdc
    Terminationssilver-plated end terminations, solder immersion compatible
    Typical melting I2t38.74 A²s
    Voltage rating, DC125 Vdc

    Behaviour Under Load

    A surface-mount fuse is soldered in, so it protects the board once and then has to be replaced by rework. That changes the economics: the part is chosen to be fast enough to save the trace, and the trace is designed to survive the let-through of the fuse rather than the full fault current.

    Decoding the Order Code

    1025FA is the family, 5 is the current rating - 5 A, written without a decimal point - and -R is the RoHS suffix.

    A packaging prefix such as TR2- goes in front of the whole code and changes only the reel quantity.

    The Secondary Columns

    The secondary columns are where the layout decisions live. The cold resistance is 0.0195 Ω, which is what the circuit sees before the element warms. Melting takes 38.74 A²s, so a fault has to deliver that much energy before the element even starts to go. At rated current the drop is 180 mV.

    This Rating in Context

    At this rating the element is carrying real current and the cold resistance is in the tens of milliohms. The fuse no longer affects the circuit in normal operation, but the energy it has to clear on a fault is larger - which is where the interrupting rating starts to matter.

    The step below is 1025FA4-R at 4 A, the step above is 1025FA7-R at 7 A. The package and the land pattern are identical across the three; only the element changes.

    Before You Order

    The 1025 body is 10.29 x 2.77 mm - noticeably longer than a 1206. On a dense board that extra length is what forces a layout change, so check the land pattern before specifying it as a substitute for a smaller part.

    Fitting a different speed in the same body is the error to avoid. The package will accept either, the board will not: a fast part in a delay position opens on every start, and a delay part in a fast position lets a fault through for longer than the downstream part can take.

    Approvals

    UL Recognition, Guide JDYX2, File E19180 (250 mA - 15 A); CSA component acceptance.

    For equipment exported to several markets, check each mark separately. The European and North American approvals on this family do not always cover the same current band.

    FAQ

    Is the fuse polarity sensitive?
    No. A chip fuse is symmetric and can be placed either way round. The marking on the body identifies the rating, not the direction.

    What does MSL mean for this part?
    Moisture sensitivity level - how long the part can sit out of its dry pack before reflow. Parts at MSL 1 have no floor life limit; higher levels need baking or dry storage before the reflow cycle.

    Are these parts AEC-Q200 qualified?
    Only where the data sheet says so. The qualification is listed per family and sometimes per current range; a part number in the same series is not automatically covered.

    Design note: the figures above are Technical Data 4322, measured at 25 °C on the reference land pattern. Check the rating against the actual copper area and the ambient inside the enclosure before release.

    Mechanical Dimensions

    eaton-1025fa-surface-mount-fuse-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.