Compact 2410 / 6125 NANO2 protection at 500 mA, Littelfuse 0452.500NRL, time-lag (Slo-Blo).
    • Product Details
    • Download

    500 mA time-lag (Slo-Blo) Surface-Mount Fuse – Littelfuse 0452.500NRL

    Littelfuse 0452.500NRL is specified at 500 mA and 125 VAC/VDC, giving designers a compact time-lag (Slo-Blo) fuse for board-level protection. The -55 °C to +125 °C operating range broadens its use across compact power-conversion and control assemblies. A nominal cold resistance of 0.7000 Ω helps quantify conduction loss, while the 0.240 A²s nominal melting I²t supports pulse-energy review.

    Best fit: battery charging circuits using a 500 mA protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 500 mA time-lag (Slo-Blo) protection for circuits up to 125 VAC/VDC
    • 0.7000 Ω nominal cold resistance for loss and voltage-drop estimation
    • 0.240 A²s nominal melting I²t for pulse-withstand and coordination review
    • 50 A @ 125 VAC/VDC; 300 A @ 32 VDC interrupting capability
    • UL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 452 Series
    Part number0452.500NRL
    Fuse characteristictime-lag (Slo-Blo)
    Rated current500 mA
    Voltage rating125 VAC/VDC
    Interrupting rating50 A @ 125 VAC/VDC; 300 A @ 32 VDC
    Nominal cold resistance0.7000 Ω
    Nominal melting I²t0.240 A²s
    Package2410 / 6125 NANO2
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Best-Fit Applications

    • battery charging circuits
    • telecom and networking equipment
    • power supplies with startup surge

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 500 mA rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 50 A @ 125 VAC/VDC; 300 A @ 32 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 2410 / 6125 NANO2 package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0452.500NRL within the 452 Series?
    Its defining electrical point is 500 mA with a 125 VAC/VDC maximum rating and time-lag (Slo-Blo) opening behavior.

    Can 0452.500NRL be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0452.500NRL intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 2410 / 6125 NANO2 construction.

    Ordering and Packaging

    Packaging: 1,000-piece MR or 5,000-piece NR tape-and-reel; L suffix identifies the RoHS/halogen-free gold-cap version.

    Ordering reference: start with 0452.500NRL and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.

    Shenzhen Gaorunxin Technology Co., Ltd