5CLE-15E Eaton Bussmann 4.8kV 15A Class E Medium Voltage Fuse
5CLE-15E Eaton Bussmann 4.8kV 15A Class E Medium Voltage Fuse

5CLE-15E Eaton Bussmann 4.8kV 15A Class E Medium Voltage Fuse

Share
pEaton Bussmann 5CLE-15E, 4.8kV 15A Class E medium voltage fuse, 50 kAIC interrupting. For transformer, feeder and switchgear protection./p
    • Product Details
    • Download

    5CLE-15E Eaton Bussmann 4.8kV 15A Class E Medium Voltage Fuse

    At a Glance
    • 4.8 kV rated voltage, 15 A rated current
    • 50 kAIC interrupting rating
    • Class E time-current characteristic

    The Eaton Bussmann 5CLE-15E is a fuse with 4.8 kV rated voltage, 15 A rated current, 50 kAIC interrupting capacity, carrying a Class E time-current characteristic.

    Specifications

    General specifications
    UPC051712528610
    Product Length/Depth12.9 in
    Product Height2 in
    Product Width2 in
    Product Weight6 lb
    Electrical rating
    Amperage Rating15 A
    Interrupt rating50 kAIC
    Voltage rating4.8 kV
    General information
    ClassClass E
    Special featuresIndoor, single barrel

    Series Selection Table

    5CLE-15E series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Energy and utility distribution
    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann 5CLE-15E?
    4.8 kV / 15 A, with a 50 kAIC interrupting rating.
    How much fault current can the 5CLE-15E interrupt?
    50 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class E mean for the 5CLE-15E?
    Class E defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the 5CLE-15E for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message