6.3 A 125 Vac Fast-Blow Ceramic Fuse - Eaton 6125FA6.3A
6.3 A 125 Vac Fast-Blow Ceramic Fuse - Eaton 6125FA6.3A

6.3 A 125 Vac Fast-Blow Ceramic Fuse - Eaton 6125FA6.3A

Share
pEaton 6125FA6.3A: 6.3 A fast-acting SMD fuse, 6.3 x 2.5 mm (2410 imperial / 6125 metric), 125 Vac. Ordering code TR2/6125FA6.3A./p
    • Product Details
    • Download

    6.3 A 125 Vac Fast-Blow Ceramic Fuse - Eaton 6125FA6.3A

    6.3 A at 125 Vac - fast-acting, 6.3 x 2.5 mm surface-mount, EIA/IS-722.
    Supplied as TR2/6125FA6.3A - 5,000 pieces on 12 mm tape-and-reel, one 13 inch (330 mm) reel.

    Specifications

    Part number6125FA6.3A
    Ordering codeTR2/6125FA6.3A
    Packaging5,000 pcs on 12 mm tape-and-reel, 13 in (330 mm) reel, EIA-481
    Rated current6.3 A
    Typical melting I2t14 A²s
    Typical cold resistance0.012 Ω
    Agency approvalCSA component acceptance 053787 C 000, Class 1422-30; UL Recognition Guide JDYX2, File E19180
    Design standardEIA/IS-722
    Interrupting rating50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc
    Voltage rating125 Vac / 125 Vdc / 86 Vdc
    Terminationsnickel/silver plated end terminations, solder immersion compatible
    Typical voltage drop0.12 V
    Package6.3 x 2.5 mm (2410 imperial / 6125 metric)

    Reading the Numbers

    Read the row from the right. The cold resistance is 0.012 Ω, which is what the circuit sees before the element warms. Melting takes 14 A²s, so a fault has to deliver that much energy before the element even starts to go. At rated current the drop is 0.12 V. The ratings on the left only say when those figures apply.

    How This Fuse Behaves

    Heat leaves a chip fuse through the end terminations and into the copper, so the land pattern is part of the thermal design. A part on a narrow trace runs hotter than the same part on a pour, and opens earlier than the data sheet suggests.

    Reading the Part Number

    6125FA is the family, 6.3A is the current rating in amps (6.3 A), and -R is the RoHS suffix. The decimal is part of the rating, not a version number.

    Where This Rating Sits

    At this rating the element is carrying real current and the cold resistance is in the tens of milliohms. The fuse no longer affects the circuit in normal operation, but the energy it has to clear on a fault is larger - which is where the interrupting rating starts to matter.

    The step below is 6125FA5A at 5 A, the step above is 6125FA7A at 7 A. The package and the land pattern are identical across the three; only the element changes.

    Standards and Approvals

    CSA component acceptance 053787 C 000, Class 1422-30; UL Recognition Guide JDYX2, File E19180.

    The data sheet states the range each approval covers. Where a part is being used outside that range - typically at the top of the current scale - the file number no longer applies even though the part number does.

    Selecting and Replacing

    This family quotes three voltage/current pairs, not one. The 125 V AC and 125 V DC ratings give 50 A and 300 A of interrupting capacity, while the 86 V DC rating gives 10,000 A. Pick the row that matches the voltage the circuit can actually apply, not the biggest number in the table.

    A like-for-like replacement is a straight swap only if the speed matches. Where the previous part was chosen for a different load, replacing it with the same rating keeps the original mistake in place.

    Common Questions

    How is the part marked?
    With a short code that identifies the rating, not the full part number. On a small body that code is a single letter or digit, which is why a mismatched reel is hard to spot once the parts are out of their packaging.

    Does the land pattern affect the rating?
    Yes. Heat leaves through the terminations, so a part on a narrow trace runs hotter than the same part on a copper pour. Eaton specifies the rating at 25 °C on a reference land; a tight layout derates it.

    Why does the table list a typical voltage drop?
    Because the fuse is in series with the load and its resistance is not zero. On a low voltage rail a few hundred millivolts of drop is a real fraction of the headroom, especially at the higher current ratings.

    Design note: the figures above are Technical Data 2531, measured at 25 °C on the reference land pattern. Check the rating against the actual copper area and the ambient inside the enclosure before release.

    Shenzhen Gaorunxin Technology Co., Ltd