71FE Eaton Bussmann 690VAC 71A High Speed Fuse
71FE Eaton Bussmann 690VAC 71A High Speed Fuse

71FE Eaton Bussmann 690VAC 71A High Speed Fuse

Share
Eaton Bussmann 71FE, 690VAC, 71A high speed fuse, 200kA (a.c.) interrupting.
    • Product Details
    • Download
    At a Glance
    • Rated current 71A
    • Rated voltage 690VAC
    • Interrupting rating 200kA (a.c.)

    The Eaton Bussmann 71FE is a high speed fuse rated 690VAC at 71A and with a 200kA (a.c.) interrupting rating. It is used for DC links and semiconductor stacks that need sub-millisecond clearing. British standard fuse, Single barrel, 71A, 690 VAC/500 VDC (IEC), 700 VAC/500 VDC (UL), Class aR, Breaking capacity 200 kA RMS Sym., 50 kA DC at 500 VDC.

    Key Specifications

    Catalog Number71FE
    SeriesBussmann BS88 FE
    Product TypeBS88 high speed fuse link (bolted tags)
    Rated Voltage AC690V a.c. (IEC) / 700V a.c. (UL)
    Rated Voltage DC500V d.c.
    Rated Current71A
    Breaking Capacity200kA (a.c.)
    Pre-arcing I²t210 A²s
    Clearing I²t at 415 V / 660 V a.c.600 / 950 A²s
    Power Loss at Rated Current17 W
    StandardsBS88 part 4, IEC 60269-4, UL Recognized
    ApplicationProtection of power semiconductors, rectifiers, DC drives and power converters
    DimensionsFull size drawing ↓

    Applications

    Protection of power semiconductors, rectifiers, DC drives and power converters.

    DC links and semiconductor stacks that need sub-millisecond clearing.

    Selection Notes

    Match the fuse I²t to the device it protects; a larger fuse protects the cable but not the semiconductor.

    For DC circuits confirm the time constant, since clearing time depends on the circuit L/R.

    Common Questions

    What is the 71FE rated for?

    It is rated 690VAC at 71A. The interrupting rating is 200kA (a.c.).

    What class is this fuse?

    The class is not stated on the manufacturer page; confirm on the datasheet before ordering.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number 71FE; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for 71FE. Verify ratings against the current datasheet before ordering.

    Shenzhen Gaorunxin Technology Co., Ltd