A4BY5000 Eaton Bussmann 600VAC 5000A Class L Fuse
A4BY5000 Eaton Bussmann 600VAC 5000A Class L Fuse

A4BY5000 Eaton Bussmann 600VAC 5000A Class L Fuse

Share
Eaton Bussmann A4BY5000, 600VAC, 5000A class l fuse, 50kA interrupting.
    • Product Details
    • Download
    At a Glance
    • Rated current 5000A
    • Rated voltage 600VAC
    • Interrupting rating 50kA
    • Class L Fuse class

    The Eaton Bussmann A4BY5000 is a class l fuse rated 600VAC at 5000A and with a 50kA interrupting rating. It is used for service and feeder protection in large distribution equipment. 1200A 600VAC, Class L Fuse,Current Limiting Fuse, Time Delay, Bussmann Cross Reference: KLU Fuse, Mersen Fuse.

    Key Specifications

    Product NameMersen/Ferraz Amp-Trap Class L Fuse A4BY Series
    Catalog NumberA4BY5000
    Rated Amperage5000A
    Rated Voltage600VAC,300VDC
    Product Height273 mm
    Product Diameter159 mm
    Product Weight10.7 kg
    ClassClass L Fuse
    Voltage TypeAC
    Breaking Capacity50kA
    3D Model / CADstp
    ConnectionBolted
    Bussmann Cross ReferenceKLU-5000
    CertificationUL

    Same-Series Models

    ModelCurrentVoltageClass
    A4BY650650A600VACClass L Fuse
    A4BY800800A600VACClass L Fuse
    A4BY10001000A600VACClass L Fuse
    A4BY12001200A600VACClass L Fuse
    A4BY12001200A600VACClass L Fuse
    A4BY16001600A600VACClass L Fuse
    A4BY20002000A600VACClass L Fuse
    A4BY50005000A600VACClass L Fuse

    8 models in the A4BY family, sorted by rated current.

    Standards & Approvals

    UL — as listed by the manufacturer for this catalog number. Confirm the current certificate before design freeze.

    Applications

    Service and feeder protection in large distribution equipment.

    Common Questions

    What is the A4BY5000 rated for?

    It is rated 600VAC at 5000A. The interrupting rating is 50kA. It is a Class L Fuse fuse.

    What class is this fuse?

    Class L Fuse.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number A4BY5000; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for A4BY5000. Verify ratings against the current datasheet before ordering.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message