ACF/ACF-A Conquer Power Fuse 35-40A
ACF/ACF-A Conquer Power Fuse 35-40A

ACF/ACF-A Conquer Power Fuse 35-40A

Share
pConquer ACF/ACF-A, power fuse, 35-45A amperage range, 7.0Ø x 32.5mm, Fast-Acting./p
    • Product Details
    • Download

    ACF/ACF-A Conquer Power Fuse 35-40A

    At a Glance
    • 35 ~ 45 A amperage rating
    • 7.0Ø x 32.5mm footprint
    • Fast-Acting characteristic
    • Operating temperature -55 ºC to 125 ºC
    • 2 catalog numbers available in this series

    The Conquer ACF/ACF-A is a power fuse rated 35-45A, in a 7.0Ø x 32.5mm case. It is a fast-acting device.

    Specifications

    Ampere Rating35 ~ 45 A
    Size7.0Ø x 32.5mm
    CharacteristicFast-Acting
    Operating Temperature-55 ºC to 125 ºC

    Available Ratings

    Every catalog number in this series is listed below with its current rating, voltage, cold resistance and melting I²t. Order by the catalog number, not by the series name.

    Catalog NumberCurrentVoltageCold RMelting I²tMarking
    ACF / ACF-A 03535A500V0.00328 Ω12.3 A²s—
    ACF / ACF-A 04040A500V0.00265 Ω14.0 A²s—

    Cold resistance measured at ≤10% of rated current at 25 °C; melting I²t at 1000% of current rating.

    Features & Benefits

    • High Current Rated
    • High Voltage Rating
    • Available in Cartrige

    Applications

    • AI Server Power
    • Data Center
    • Power Supply
    • Inverters

    Selection Notes

    • Fast-acting fuses open quickly on overload; use them where the protected device has no surge tolerance, and check the inrush against the time-current curve before specifying.
    • Rated operating temperature -55 ºC to 125 ºC; derate the ampere rating for continuous operation near the upper limit.

    Common Questions

    What amperage ratings does the ACF/ACF-A cover?
    35 ~ 45 A, across 2 catalog numbers.
    Which catalog number should I order for a specific current?
    The series runs from ACF / ACF-A 035 (35A) to ACF / ACF-A 040 (40A). See the Available Ratings table above for the exact catalog number, cold resistance and melting I²t of each rating.
    What is the footprint of the ACF/ACF-A?
    7.0Ø x 32.5mm. Confirm the land pattern against the datasheet before layout.
    Where is the full datasheet for the ACF/ACF-A?
    The series datasheet is published by Conquer and linked at the bottom of this page (PDF).

    Datasheet

    Download the Power Fuse series PDF

    The PDF covers the whole series, including time-current curves and agency approvals.