CRG40T60AN3S-N CR Micro 650V 40A IGBT TO-3PN
CRG40T60AN3S-N CR Micro 650V 40A IGBT TO-3PN

CRG40T60AN3S-N CR Micro 650V 40A IGBT TO-3PN

Share
pCRG40T60AN3S-N CR Micro 650V 40A IGBT TO-3PN — VCE(sat) 1.8 V, Eoff 0.97 mJ./p
    • Product Details
    • Download
    At a Glance
    • 650 V / 40 A continuous collector current, TO-3PN
    • VCE(sat) 1.8 V
    • Eoff 0.97 mJ per turn-off
    • Trench FS III technology

    The CR Micro CRG40T60AN3S-N is a 650 V 40 A IGBT in a TO-3PN package. Its saturation voltage is 1.8 V; turn-off loss is 0.97 mJ per pulse; the anti-parallel diode drops 1.5 V. The die is built on Trench FS III technology.

    Key Specifications

    Collector-Emitter Voltage (VCES)650 V
    Continuous Collector Current (IC)40 A
    Collector-Emitter Saturation (VCE(sat))1.8 V
    Gate-Emitter Voltage (VGE)5.7 V
    Turn-off Loss (Eoff)0.97 mJ
    Diode Forward Voltage (VF)1.5 V
    TechnologyTrench FS III
    PackageTO-3PN

    Same-Rating Selection Table

    Part NumberVCESICVCE(sat)EoffVFTechnologyPackage
    CRG40T60AN3H-N650V40A1.9V0.821.4VTrench FS IIITO-3PN
    CRG40T60AN3S-N650V40A1.8V0.971.5VTrench FS IIITO-3PN
    CRG40T65AN5H-N650V40A1.7V0.721.33VTrench FS ⅤTO-3PN
    CRG60T60AN3H-N650V60A1.9V1.391.3VTrench FS IIITO-3PN

    4 part numbers share the same 650 / TO-3PN rating — sorted by current.

    Process Technology

    Trench FS III refers to a trench-gate field-stop structure. Field-stop layers let the wafer be thinned while keeping the blocking voltage, which cuts both saturation voltage and turn-off loss. The roman numeral is the generation: later generations trade conduction loss for switching speed.

    Applications

    Active PFC, server and telecom rectifiers, and half-bridge or full-bridge DC-DC with 650 V bus.

    Selection Notes

    • VCE(sat) is quoted at a specific collector current and gate voltage. Re-check the datasheet curve at your actual operating current and junction temperature.
    • Eoff trades directly against VCE(sat). Faster technology generations give lower Eoff at equal saturation, which is why a newer generation can run at a higher switching frequency.
    • Check the short-circuit withstand time before using the part in a drive with a hard fault path.
    • Confirm whether the anti-parallel diode is co-packaged or separate — the VF figure above refers to the internal diode where one is present.

    Common Questions

    What is the blocking voltage of the CRG40T60AN3S-N?

    VCES is 650 V, with a continuous collector current of 40 A.

    What is the saturation voltage of the CRG40T60AN3S-N?

    VCE(sat) is 1.8 V at the rated current and gate voltage stated in the datasheet.

    How much switching loss does the CRG40T60AN3S-N have?

    Turn-off loss Eoff is 0.97 mJ per pulse under the test conditions in the datasheet. Switching loss scales with bus voltage and current, so recalculate for your operating point.

    What technology does the CRG40T60AN3S-N use?

    Trench FS III. Field-stop trench structures raise the electric field in the drift region while keeping the wafer thin, which lowers both VCE(sat) and Eoff against a planar IGBT.

    What package does the CRG40T60AN3S-N come in?

    TO-3PN. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.

    How do I choose between the 4 part numbers in this rating group?

    All 4 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message