The CR Micro CRM50TD06R1 is a 500 V 6 A intelligent power module in a QFN 7x7 package, wired as a half-bridge using MOSFET power stages. Protection on board covers under-voltage lockout. Designed for Fans and Hair dryer.
| Blocking Voltage (VDSS / VCES) | 500 V |
| Output Current (ID / IC) | 6 A |
| Power Stage | MOSFET |
| Circuit Configuration | half-bridge |
| Rds(on) typ. | 1.1 mΩ |
| Rds(on) max. | 1.4 mΩ |
| Built-in Protection | vot |
| Typical Application | Fans and Hair dryer |
| Package | QFN 7x7 |
| Part Number | VDSS/VCES | ID/IC | Configuration | VCE(sat) typ | Package |
|---|---|---|---|---|---|
| CRM50TD02R1 | 500V | 2A | half-bridge | QFN 7x7 | |
| CS5752BSCO | 500V | 2A | half-bridge | TWSOP13 | |
| CRM50TE03FA | 500V | 3A | half-bridge | 1.2V | SOP-11 |
| CRM50TD04R1 | 500V | 4A | half-bridge | QFN 7x7 | |
| CRM50TE04FA | 500V | 4A | half-bridge | SOP-11 | |
| CS5754BSCO | 500V | 4A | half-bridge | TWSOP13 | |
| CS5754SCO | 500V | 4A | half-bridge | TWSOP13 | |
| CS5754SDQ | 500V | 4A | half-bridge | QFN18 | |
| CS5754STF | 500V | 4A | half-bridge | QFN18 | |
| CRM50TE05FA | 500V | 5A | half-bridge | SOP-11 | |
| CRM50TF05FA | 500V | 5A | half-bridge | ESOP-9 | |
| CRM50TF05GA | 500V | 5A | half-bridge | ESOP-9 | |
| CS5755ASCO | 500V | 5A | half-bridge | WSOP13 | |
| CS5755BSCO | 500V | 5A | half-bridge | TWSOP13 | |
| CS5755SCO | 500V | 5A | half-bridge | TWSOP13 | |
| CS5755SDQ | 500V | 5A | half-bridge | QFN18 | |
| CRM50TD06R1 | 500V | 6A | half-bridge | QFN 7x7 | |
| CRM50TE07FA | 500V | 7A | half-bridge | SOP-11 | |
| CRM50TF07FA | 500V | 7A | half-bridge | ESOP-9 |
19 part numbers share the same 500 / half-bridge rating — sorted by current.
Fans and Hair dryer — the module's rating and package are sized for this class of load.
What topology does the CRM50TD06R1 implement?
It is a half-bridge module rated 500 V / 6 A.
What protection is built into the CRM50TD06R1?
The module integrates under-voltage lockout. External fault handling still has to latch the fault signal and sequence a safe restart.
What applications is the CRM50TD06R1 intended for?
Fans and Hair dryer — a match for the module's power rating and package thermal path.
What package does the CRM50TD06R1 come in?
QFN 7x7. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.
How do I choose between the 19 part numbers in this rating group?
All 19 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd