The CR Micro CRM60TE06HA is a 600 V 6 A intelligent power module in a SOP-11 package, wired as a half-bridge using MOSFET power stages. Protection on board covers over-current, fault output, short-circuit and under-voltage lockout. Designed for Air conditioner and Fans.
| Blocking Voltage (VDSS / VCES) | 600 V |
| Output Current (ID / IC) | 6 A |
| Power Stage | MOSFET |
| Circuit Configuration | half-bridge |
| Rds(on) typ. | 1.8 mΩ |
| Rds(on) max. | 2.3 mΩ |
| Built-in Protection | ocp, fo, sd, vot |
| Typical Application | Air conditioner and Fans |
| Package | SOP-11 |
| Part Number | VDSS/VCES | ID/IC | Configuration | VCE(sat) typ | Package |
|---|---|---|---|---|---|
| CRM60TD01R1 | 600V | 1A | half-bridge | QFN 7x7 | |
| CS5762ASCO | 600V | 2A | half-bridge | WSOP13 | |
| CRM60TD03R1 | 600V | 3A | half-bridge | QFN 7x7 | |
| CS5763AHMO | 600V | 3A | half-bridge | ESOP12 | |
| CRM60TE04HA | 600V | 4A | half-bridge | SOP-11 | |
| CS5764AHMO | 600V | 4A | half-bridge | ESOP12 | |
| CS5764ASCO | 600V | 4A | half-bridge | WSOP13 | |
| CS5764SCO | 600V | 4A | half-bridge | WSOP13 | |
| CS5764SDQ | 600V | 4A | half-bridge | QFN18 | |
| CRM60TD05R1 | 600V | 5A | half-bridge | QFN 7x7 | |
| CS5765AHGO | 600V | 5A | half-bridge | 1.5V | ESOP12 |
| CS5765ASGO | 600V | 5A | half-bridge | 1.5V | WSOP13 |
| CS5765SGO | 600V | 5A | half-bridge | 1.5V | WSOP13 |
| CS5765SGQ | 600V | 5A | half-bridge | 1.5V | QFN18 |
| CRM60TE06HA | 600V | 6A | half-bridge | SOP-11 | |
| CS5766AHMO | 600V | 6A | half-bridge | ESOP12 | |
| CS5766ASCO | 600V | 6A | half-bridge | WSOP13 |
17 part numbers share the same 600 / half-bridge rating — sorted by current.
Air conditioner and Fans — the module's rating and package are sized for this class of load.
What topology does the CRM60TE06HA implement?
It is a half-bridge module rated 600 V / 6 A.
What protection is built into the CRM60TE06HA?
The module integrates over-current, fault output, short-circuit, under-voltage lockout. External fault handling still has to latch the fault signal and sequence a safe restart.
What applications is the CRM60TE06HA intended for?
Air conditioner and Fans — a match for the module's power rating and package thermal path.
What package does the CRM60TE06HA come in?
SOP-11. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.
How do I choose between the 17 part numbers in this rating group?
All 17 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd