CS5735MTO CR Micro 300V 5A IPM SOP-23H
CS5735MTO CR Micro 300V 5A IPM SOP-23H

CS5735MTO CR Micro 300V 5A IPM SOP-23H

Share
pCS5735MTO CR Micro 300V 5A IPM SOP-23H — 3-phase full bridge./p
    • Product Details
    • Download
    At a Glance
    • 300 V / 5 A output rating, SOP-23H
    • 3-phase full bridge topology

    The CR Micro CS5735MTO is a 300 V 5 A intelligent power module in a SOP-23H package, wired as a 3-phase full bridge using MOSFET power stages. Protection on board covers under-voltage lockout. Designed for Fans and Hair dryer.

    Key Specifications

    Blocking Voltage (VDSS / VCES)300 V
    Output Current (ID / IC)5 A
    Power StageMOSFET
    Circuit Configuration3-phase full bridge
    Rds(on) typ.1.2 mΩ
    Rds(on) max.1.5 mΩ
    Built-in Protectionvot
    Typical ApplicationFans and Hair dryer
    PackageSOP-23H

    Same-Rating Selection Table

    Part NumberVDSS/VCESID/ICConfigurationVCE(sat) typPackage
    CS5735MTO300V5A3-phase full bridgeSOP-23H
    CS5738NTO300V8A3-phase full bridgeSOP-23H

    2 part numbers share the same 300 / 3-phase full bridge rating — sorted by current.

    Applications

    Fans and Hair dryer — the module's rating and package are sized for this class of load.

    Selection Notes

    • The module integrates gate drive and protection. The input side expects logic-level PWM, not a raw gate signal — do not add an external driver.
    • Fault output is open-drain on most of these modules. Fit a pull-up and latch it in the controller, otherwise the module restarts into a fault.
    • Check the dead time and minimum pulse width in the datasheet. The internal interlock is a protection layer, not a substitute for correct timing.
    • Thermal design dominates reliability. Use the module's internal thermistor or the case-to-heatsink path to size the heatsink for the actual switching loss.

    Common Questions

    What topology does the CS5735MTO implement?

    It is a 3-phase full bridge module rated 300 V / 5 A.

    What protection is built into the CS5735MTO?

    The module integrates under-voltage lockout. External fault handling still has to latch the fault signal and sequence a safe restart.

    What applications is the CS5735MTO intended for?

    Fans and Hair dryer — a match for the module's power rating and package thermal path.

    What package does the CS5735MTO come in?

    SOP-23H. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.

    How do I choose between the 2 part numbers in this rating group?

    All 2 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.

    Shenzhen Gaorunxin Technology Co., Ltd