DPM15DH60WGTM CR Micro 600V 15A IPM SIP35
DPM15DH60WGTM CR Micro 600V 15A IPM SIP35

DPM15DH60WGTM CR Micro 600V 15A IPM SIP35

Share
pDPM15DH60WGTM CR Micro 600V 15A IPM SIP35 — 3-phase full bridge、PFC./p
    • Product Details
    • Download
    At a Glance
    • 600 V / 15 A output rating, SIP35
    • 3-phase full bridge、PFC topology
    • VCE(sat) 1.7 V typ
    • Integrated over-current, fault output, short-circuit

    The CR Micro DPM15DH60WGTM is a 600 V 15 A intelligent power module in a SIP35 package, wired as a 3-phase full bridge、PFC using IGBT power stages. Protection on board covers over-current, fault output and short-circuit. Saturation voltage is 1.7 V typical. Designed for air condition.

    Key Specifications

    Blocking Voltage (VDSS / VCES)600 V
    Output Current (ID / IC)15 A
    Power StageIGBT
    Circuit Configuration3-phase full bridge、PFC
    VCE(sat) typ.1.7 V
    VCE(sat) max.2.2 V
    Built-in Protectionocp, fo, sd
    Typical Applicationair condition
    PackageSIP35

    Same-Rating Selection Table

    Part NumberVDSS/VCESID/ICConfigurationVCE(sat) typPackage
    DPM15DH60WGK600V15A3-phase full bridge、PFC1.7VSIP35
    DPM15DH60WGTK600V15A3-phase full bridge、PFC1.7VSIP35
    DPM15DH60WGTM600V15A3-phase full bridge、PFC1.7VSIP35

    3 part numbers share the same 600 / 3-phase full bridge、PFC rating — sorted by current.

    Applications

    air condition — the module's rating and package are sized for this class of load.

    Selection Notes

    • The module integrates gate drive and protection. The input side expects logic-level PWM, not a raw gate signal — do not add an external driver.
    • Fault output is open-drain on most of these modules. Fit a pull-up and latch it in the controller, otherwise the module restarts into a fault.
    • Check the dead time and minimum pulse width in the datasheet. The internal interlock is a protection layer, not a substitute for correct timing.
    • Thermal design dominates reliability. Use the module's internal thermistor or the case-to-heatsink path to size the heatsink for the actual switching loss.

    Common Questions

    What topology does the DPM15DH60WGTM implement?

    It is a 3-phase full bridge、PFC module rated 600 V / 15 A.

    What protection is built into the DPM15DH60WGTM?

    The module integrates over-current, fault output, short-circuit. External fault handling still has to latch the fault signal and sequence a safe restart.

    What applications is the DPM15DH60WGTM intended for?

    air condition — a match for the module's power rating and package thermal path.

    What package does the DPM15DH60WGTM come in?

    SIP35. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.

    How do I choose between the 3 part numbers in this rating group?

    All 3 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.

    Shenzhen Gaorunxin Technology Co., Ltd