Eaton 0402ESDA-MLP ESD Suppressor
Eaton 0402ESDA-MLP ESD Suppressor

Eaton 0402ESDA-MLP ESD Suppressor

Share
0402ESDA-MLP: ESD protection suppressor, 30 V rated, 35 V clamp, 0.05 pF.
    • Product Details
    • Download

    Eaton 0402ESDA-MLP ESD Suppressor

    0402ESDA-MLP at a glance: ESD protection suppressor, 30 V rated, 35 V clamp, 0.05 pF.

    Key Specifications

    ParameterValue
    Orderable part number0402ESDA-MLP
    Rated voltage, maximum30 Vdc
    Clamping voltage, typical35 V
    Trigger voltage, typical300 V
    Capacitance at 1 MHz, typical0.05 pF
    Capacitance at 1 MHz, maximum0.15 pF
    Attenuation change, 0-6 GHz-0.2 dB typical
    Leakage current at 12 Vdcmax. 0.1 nA
    ESD capability, IEC 61000-4-28 kV contact / 15 kV air
    ESD pulse withstand>1000 pulses
    Channels1
    Package0402 (1005 metric)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 4367

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 4367; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    An ESD rating is a qualification, not a life count: IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive that repeatedly because the energy per event is small.

    At 0.05 pF the part is effectively invisible to a multi-gigabit pair: the reactance at 1 GHz is still in the hundreds of ohms, far above the differential impedance.

    Within the 0402ESDA family this is item 2 of 2 in the Eaton catalogue.

    Where This Series Fits

    Route the protected line through the pad and out the other side where the package allows it. A stub that tees off the line leaves a reflection that shows up as a glitch on a high speed pair.

    • Capacitance is not a small effect on a data line. Read the capacitance at the frequency the line actually carries, not the 1 MHz test figure alone.
    • The pulse withstand count is a qualification figure at a defined level. Repeated discharges at a higher level reduce it, so a port that sees frequent events needs margin.

    Frequently Asked Questions

    Does it affect signal integrity?
    Through its capacitance. At 0.1 pF the effect is negligible at several gigahertz; at 1 pF it is visible on a fast differential pair, so the capacitance grade is part of the selection.

    Does the package matter?
    It sets the capacitance and the thermal mass. The same die in a 0201 and a 0603 gives different surge capability, so the package is part of the electrical choice, not just the footprint.

    What does bidirectional mean in practice?
    The part clamps either polarity with the same characteristic, so it can be placed either way round and protects a line that swings below ground.