0603ESDA2-TR2: ESD protection suppressor, 35 V clamp, 0.1 pF.
    • Product Details
    • Download

    Eaton 0603ESDA2-TR2 ESD Suppressor

    0603ESDA2-TR2 at a glance: ESD protection suppressor, 35 V clamp, 0.1 pF.

    Key Specifications

    ParameterValue
    Orderable part number0603ESDA2-TR2
    Clamping voltage, typical35 V
    Trigger voltage, typical350 V
    Capacitance at 1 MHz, typical0.1 pF
    Capacitance at 1 MHz, maximum0.15 pF
    Leakage current at 12 Vdcmax. 0.1 nA
    ESD capability, IEC 61000-4-28 kV contact / 15 kV air
    Peak current30 A typ / 45 A max
    ESD pulse withstand>1000 pulses
    Channels1
    Package0603 (1608 metric)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 4419

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 4419; the package line above is the
    body the part is built in.

    The Figures Explained

    These devices are bidirectional and symmetric, so they can be placed either way round on the board. That removes the orientation error that a diode pair invites on a differential pair.

    At 0.1 pF the part is effectively invisible to a multi-gigabit pair: the reactance at 1 GHz is still in the hundreds of ohms, far above the differential impedance.

    Within the 0603ESDA family this is item 1 of 4 in the Eaton catalogue.

    Series Positioning

    Route the protected line through the pad and out the other side where the package allows it. A stub that tees off the line leaves a reflection that shows up as a glitch on a high speed pair.

    • Capacitance is not a small effect on a data line. Read the capacitance at the frequency the line actually carries, not the 1 MHz test figure alone.
    • The pulse withstand count is a qualification figure at a defined level. Repeated discharges at a higher level reduce it, so a port that sees frequent events needs margin.

    Frequently Asked Questions

    Is the suppressor fast enough for a cable discharge?
    The response is in the sub-nanosecond range because the structure is a junction, not a spark gap. What limits the protection is the layout, not the die.

    Can it be used on a power rail?
    Yes, within the rated voltage, but the energy per event on a power rail is much higher than an ESD strike. For supply transients a TVS with a joule rating is the right part, not an ESD suppressor.

    Does the package matter?
    It sets the capacitance and the thermal mass. The same die in a 0201 and a 0603 gives different surge capability, so the package is part of the electrical choice, not just the footprint.