pEaton 0603FA2.5-R — 2.5 A, 32 V, fast-acting SMD fuse, 35 A at rated voltage interrupting./p
    • Product Details
    • Download

    Eaton 0603FA2.5-R 2.5A 32Vac/dc Fast-Acting Chip SMD Fuse

    The 0603FA2.5-R from Eaton carries 2.5 A, rated 32 Vac/dc, uses a fast-acting element, in a chip body.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesEaton / 0603FA Series
    Part number0603FA2.5-R
    Fuse characteristicfast-acting
    Current rating2.5 A
    Voltage rating32 Vac/dc
    Interrupting rating35 A at rated voltage
    Typical DC cold resistance0.037 Ω
    Typical melting I²t0.0625 A²s
    Typical voltage drop0.113 V
    Package0603 (1608 metric) chip, surface mount
    Operating temperature-55 °C to +125 °C (with derating)
    AgencyUL Recognition JDYX2 / E19180; CSA 053787 C 000, Class 1422 30
    EnvironmentalRoHS compliant and halogen free; AEC-Q200 qualified

    Practical Notes

    • Interrupting capability is 35 A at rated voltage — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Working voltage must stay at or below 32 Vac/dc; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 2.5 A to stop nuisance trips — fix the cause instead.

    Application Scenarios

    Common installation contexts include:

    • EV
    • automotive

    Buying Notes

    Order code 0603FA2.5-R from Eaton, supplied in 0603 (1608 metric) chip, surface mount. Confirm the exact suffix before release.

    Questions and Answers

    What are the ratings of the 0603FA2.5-R?

    2.5 A continuous at 32 Vac/dc, interrupting rating 35 A at rated voltage.

    Is the 0603FA2.5-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the 0603FA2.5-R be used on a higher fault-current circuit?

    No — its interrupting rating is 35 A at rated voltage. Choose a part whose breaking capacity exceeds the prospective fault current.