Eaton 1025TD1.5-R 1.5 A Slow-Blow 10.29 x 2.77 mm Ceramic Fuse
Eaton 1025TD1.5-R 1.5 A Slow-Blow 10.29 x 2.77 mm Ceramic Fuse

Eaton 1025TD1.5-R 1.5 A Slow-Blow 10.29 x 2.77 mm Ceramic Fuse

Share
pEaton 1025TD1.5-R — 1.5 A, 125 V, time-delay ceramic cartridge fuse, 10.29 x 2.77 mm, 50 A AC; 50 A 125 Vdc interrupting./p
    • Product Details
    • Download

    Eaton 1025TD1.5-R 1.5 A Slow-Blow 10.29 x 2.77 mm Ceramic Fuse

    Eaton 1025TD1.5-R 1.5 A Slow-Blow 10.29 x 2.77 mm Ceramic Fuse belongs to the Eaton range. It carries 1.5 A, rated 125 Vdc, uses a slow-blow element, in a ceramic body, measuring 29 x 2.77 mm.

    Technical Data

    ParameterRating
    Part number1025TD1.5-R
    Ordering codeTR2/1025TD1.5-R
    Packaging2,500 pcs on 24 mm tape-and-reel, 13 in (330 mm) reel, EIA-481
    Package10.29 x 2.77 mm (4010 imperial / 1025 metric)
    Voltage rating, DC125 Vdc
    Terminationssilver-plated end terminations, solder immersion compatible
    Typical melting I2t11.79 A²s
    Typical voltage drop310 mV
    Rated current1.5 A
    Agency approvalUL Recognition, Guide JDYX2, File E19180 (250 mA - 5 A); CSA component acceptance
    Voltage rating250 Vac
    Design standardEIA/IS-722
    Interrupting rating50 A AC; 50 A 125 Vdc
    Typical cold resistance0.1025 Ω

    Design Notes

    • Interrupting capability is 50 A AC; 50 A 125 Vdc — confirm the circuit's prospective fault current stays below this.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Footprint 29 x 2.77 mm — check clip or holder compatibility before substitution.
    • Working voltage must stay at or below 125 Vdc; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 1.5 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • EV

    Ordering Details

    Order code 1025TD1.5-R from Eaton, supplied in 10.29 x 2.77 mm (4010 imperial / 1025 metric). Confirm the exact suffix before release.

    Common Questions

    What are the ratings of the 1025TD1.5-R?

    1.5 A continuous at 125 Vdc, interrupting rating 50 A AC; 50 A 125 Vdc.

    Is the 1025TD1.5-R fast-acting or time-delay?

    It is slow-blow. It tolerates short inrush surges.

    What size is the 1025TD1.5-R?

    It measures 29 x 2.77 mm. Match the holder or clip to this footprint.

    Can the 1025TD1.5-R be used on a higher fault-current circuit?

    No — its interrupting rating is 50 A AC; 50 A 125 Vdc. Choose a part whose breaking capacity exceeds the prospective fault current.