Eaton 10BJ100CA TVS Diode, 162 V Clamp
Eaton 10BJ100CA TVS Diode, 162 V Clamp

Eaton 10BJ100CA TVS Diode, 162 V Clamp

Share
10BJ100CA: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 6.2 A pulse, 1000 W, bidirectional.
    • Product Details
    • Download

    Eaton 10BJ100CA TVS Diode, 162 V Clamp

    10BJ100CA at a glance: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 6.2 A pulse, 1000 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number10BJ100CA
    Standoff voltage (VR)100 V
    Leakage current at VR1 uA
    Breakdown voltage at IT111 V to 123 V
    Test current (IT)1 mA
    Clamping voltage at IPP162 V
    Peak pulse current6.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1000 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11205

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11205; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.81 percent, from 111 V to 123 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 100 V standing the leakage is at most 1 uA, so the part draws 0.1 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 10BJ family this is item 40 of 46 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.