Eaton 10BJ160CA Transient Voltage Suppressor 160 V
Eaton 10BJ160CA Transient Voltage Suppressor 160 V

Eaton 10BJ160CA Transient Voltage Suppressor 160 V

Share
10BJ160CA: transient voltage suppressor diode, 160 V standoff, 259 V clamp, 3.9 A pulse, 1000 W, bidirectional.
    • Product Details
    • Download

    Eaton 10BJ160CA Transient Voltage Suppressor 160 V

    10BJ160CA at a glance: transient voltage suppressor diode, 160 V standoff, 259 V clamp, 3.9 A pulse, 1000 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number10BJ160CA
    Standoff voltage (VR)160 V
    Leakage current at VR1 uA
    Breakdown voltage at IT178 V to 197 V
    Test current (IT)1 mA
    Clamping voltage at IPP259 V
    Peak pulse current3.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1000 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11205

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11205; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.67 percent, from 178 V to 197 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 160 V standing the leakage is at most 1 uA, so the part draws 0.16 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 10BJ family this is item 45 of 46 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.