Eaton 10BJ16CA Transient Voltage Suppressor 16 V
Eaton 10BJ16CA Transient Voltage Suppressor 16 V

Eaton 10BJ16CA Transient Voltage Suppressor 16 V

Share
10BJ16CA: transient voltage suppressor diode, 16 V standoff, 26 V clamp, 38.5 A pulse, 1000 W, bidirectional.
    • Product Details
    • Download

    Eaton 10BJ16CA Transient Voltage Suppressor 16 V

    10BJ16CA at a glance: transient voltage suppressor diode, 16 V standoff, 26 V clamp, 38.5 A pulse, 1000 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number10BJ16CA
    Standoff voltage (VR)16 V
    Leakage current at VR1 uA
    Breakdown voltage at IT17.8 V to 19.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP26 V
    Peak pulse current38.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1000 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11205

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11205; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.67 percent, from 17.8 V to 19.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 16 V standing the leakage is at most 1 uA, so the part draws 0.016 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 10BJ family this is item 15 of 46 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd