Eaton 10BJ18CA Transient Voltage Suppressor 18 V
Eaton 10BJ18CA Transient Voltage Suppressor 18 V

Eaton 10BJ18CA Transient Voltage Suppressor 18 V

Share
10BJ18CA: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 34.2 A pulse, 1000 W, bidirectional.
    • Product Details
    • Download

    Eaton 10BJ18CA Transient Voltage Suppressor 18 V

    10BJ18CA at a glance: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 34.2 A pulse, 1000 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number10BJ18CA
    Standoff voltage (VR)18 V
    Leakage current at VR1 uA
    Breakdown voltage at IT20 V to 22.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP29.2 V
    Peak pulse current34.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1000 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11205

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11205; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.5 percent, from 20 V to 22.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 18 V standing the leakage is at most 1 uA, so the part draws 0.018 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 10BJ family this is item 17 of 46 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.