Eaton 10BJ43A 43 V 1000 W TVS Diode
Eaton 10BJ43A 43 V 1000 W TVS Diode

Eaton 10BJ43A 43 V 1000 W TVS Diode

Share
10BJ43A: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 14.4 A pulse, 1000 W, unidirectional.
    • Product Details
    • Download

    Eaton 10BJ43A 43 V 1000 W TVS Diode

    10BJ43A at a glance: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 14.4 A pulse, 1000 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number10BJ43A
    Standoff voltage (VR)43 V
    Leakage current at VR1 uA
    Breakdown voltage at IT47.8 V to 52.8 V
    Test current (IT)1 mA
    Clamping voltage at IPP69.4 V
    Peak pulse current14.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1000 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11205

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11205; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.46 percent, from 47.8 V to 52.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 43 V standing the leakage is at most 1 uA, so the part draws 0.043 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 10BJ family this is item 27 of 46 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.