Eaton 10BJ45A 45 V 1000 W TVS Diode
Eaton 10BJ45A 45 V 1000 W TVS Diode

Eaton 10BJ45A 45 V 1000 W TVS Diode

Share
10BJ45A: transient voltage suppressor diode, 45 V standoff, 72.7 V clamp, 13.8 A pulse, 1000 W, unidirectional.
    • Product Details
    • Download

    Eaton 10BJ45A 45 V 1000 W TVS Diode

    10BJ45A at a glance: transient voltage suppressor diode, 45 V standoff, 72.7 V clamp, 13.8 A pulse, 1000 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number10BJ45A
    Standoff voltage (VR)45 V
    Leakage current at VR1 uA
    Breakdown voltage at IT50 V to 55.3 V
    Test current (IT)1 mA
    Clamping voltage at IPP72.7 V
    Peak pulse current13.8 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1000 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11205

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11205; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.6 percent, from 50 V to 55.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 45 V standing the leakage is at most 1 uA, so the part draws 0.045 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 10BJ family this is item 28 of 46 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.