Eaton 10BJ48CA Transient Voltage Suppressor 48 V
Eaton 10BJ48CA Transient Voltage Suppressor 48 V

Eaton 10BJ48CA Transient Voltage Suppressor 48 V

Share
10BJ48CA: transient voltage suppressor diode, 48 V standoff, 77.4 V clamp, 12.9 A pulse, 1000 W, bidirectional.
    • Product Details
    • Download

    Eaton 10BJ48CA Transient Voltage Suppressor 48 V

    10BJ48CA at a glance: transient voltage suppressor diode, 48 V standoff, 77.4 V clamp, 12.9 A pulse, 1000 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number10BJ48CA
    Standoff voltage (VR)48 V
    Leakage current at VR1 uA
    Breakdown voltage at IT53.3 V to 58 V
    Test current (IT)1 mA
    Clamping voltage at IPP77.4 V
    Peak pulse current12.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1000 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11205

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11205; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 8.818 percent, from 53.3 V to 58 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 48 V standing the leakage is at most 1 uA, so the part draws 0.048 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 10BJ family this is item 29 of 46 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products