Eaton 10BJ60A 60 V 1000 W TVS Diode
Eaton 10BJ60A 60 V 1000 W TVS Diode

Eaton 10BJ60A 60 V 1000 W TVS Diode

Share
10BJ60A: transient voltage suppressor diode, 60 V standoff, 96.8 V clamp, 10.3 A pulse, 1000 W, unidirectional.
    • Product Details
    • Download

    Eaton 10BJ60A 60 V 1000 W TVS Diode

    10BJ60A at a glance: transient voltage suppressor diode, 60 V standoff, 96.8 V clamp, 10.3 A pulse, 1000 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part number10BJ60A
    Standoff voltage (VR)60 V
    Leakage current at VR1 uA
    Breakdown voltage at IT66.7 V to 73.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP96.8 V
    Peak pulse current10.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1000 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11205

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11205; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.49 percent, from 66.7 V to 73.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 60 V standing the leakage is at most 1 uA, so the part draws 0.06 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 10BJ family this is item 33 of 46 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.