| Parameter | Value |
|---|---|
| Orderable part number | 10BJ7.0A |
| Standoff voltage (VR) | 7 V |
| Leakage current at VR | 200 uA |
| Breakdown voltage at IT | 7.78 V to 8.6 V |
| Test current (IT) | 10 mA |
| Clamping voltage at IPP | 12 V |
| Peak pulse current | 83.3 A |
| Polarity | Unidirectional |
| Peak pulse power, 10/1000 us | 1000 W |
| Package | SMB (DO-214AA) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11205 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11205; the package line above is the
body the part is built in.
The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.
The breakdown window spans 10.54 percent, from 7.78 V to 8.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 7 V standing the leakage is at most 200 uA, so the part draws 1.4 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 10BJ family this is item 4 of 46 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.