10BJ70CA: transient voltage suppressor diode, 70 V standoff, 113 V clamp, 8.8 A pulse, 1000 W, bidirectional.
    • Product Details
    • Download

    Eaton 10BJ70CA Transient Voltage Suppressor 70 V

    10BJ70CA at a glance: transient voltage suppressor diode, 70 V standoff, 113 V clamp, 8.8 A pulse, 1000 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part number10BJ70CA
    Standoff voltage (VR)70 V
    Leakage current at VR1 uA
    Breakdown voltage at IT77.8 V to 86 V
    Test current (IT)1 mA
    Clamping voltage at IPP113 V
    Peak pulse current8.8 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1000 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11205

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11205; the package line above is the
    body the part is built in.

    What the Numbers Mean

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.54 percent, from 77.8 V to 86 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 70 V standing the leakage is at most 1 uA, so the part draws 0.07 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 10BJ family this is item 35 of 46 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.