12KP20AH: transient voltage suppressor diode, 20 V standoff, 34.3 V clamp, 349.9 A pulse, 12000 W, unidirectional.
    • Product Details
    • Download

    Eaton 12KP20AH Unidirectional TVS Diode P600 axial

    12KP20AH at a glance: transient voltage suppressor diode, 20 V standoff, 34.3 V clamp, 349.9 A pulse, 12000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number12KP20AH
    Standoff voltage (VR)20 V
    Leakage current at VR15 uA
    Breakdown voltage at IT22.2 V to 24.5 V
    Test current (IT)5 mA
    Clamping voltage at IPP34.3 V
    Peak pulse current349.9 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us12000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1058

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1058; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.36 percent, from 22.2 V to 24.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20 V standing the leakage is at most 15 uA, so the part draws 0.3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 12KPE family this is item 1 of 14 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd