Eaton 12KP22CAH TVS Diode, 37.1 V Clamp
Eaton 12KP22CAH TVS Diode, 37.1 V Clamp

Eaton 12KP22CAH TVS Diode, 37.1 V Clamp

Share
12KP22CAH: transient voltage suppressor diode, 22 V standoff, 37.1 V clamp, 323.5 A pulse, 12000 W, bidirectional.
    • Product Details
    • Download

    Eaton 12KP22CAH TVS Diode, 37.1 V Clamp

    12KP22CAH at a glance: transient voltage suppressor diode, 22 V standoff, 37.1 V clamp, 323.5 A pulse, 12000 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number12KP22CAH
    Standoff voltage (VR)22 V
    Leakage current at VR10 uA
    Breakdown voltage at IT24.4 V to 26.9 V
    Test current (IT)5 mA
    Clamping voltage at IPP37.1 V
    Peak pulse current323.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us12000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1058

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1058; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.25 percent, from 24.4 V to 26.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 22 V standing the leakage is at most 10 uA, so the part draws 0.22 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 12KPE family this is item 2 of 14 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.