Eaton 12KP26CAH TVS Diode, 44 V Clamp
Eaton 12KP26CAH TVS Diode, 44 V Clamp

Eaton 12KP26CAH TVS Diode, 44 V Clamp

Share
12KP26CAH: transient voltage suppressor diode, 26 V standoff, 44 V clamp, 272.8 A pulse, 12000 W, bidirectional.
    • Product Details
    • Download

    Eaton 12KP26CAH TVS Diode, 44 V Clamp

    12KP26CAH at a glance: transient voltage suppressor diode, 26 V standoff, 44 V clamp, 272.8 A pulse, 12000 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number12KP26CAH
    Standoff voltage (VR)26 V
    Leakage current at VR5 uA
    Breakdown voltage at IT28.9 V to 31.9 V
    Test current (IT)5 mA
    Clamping voltage at IPP44 V
    Peak pulse current272.8 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us12000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1058

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1058; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.38 percent, from 28.9 V to 31.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 26 V standing the leakage is at most 5 uA, so the part draws 0.13 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 12KPE family this is item 4 of 14 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.