12KP28CAH: transient voltage suppressor diode, 28 V standoff, 47.5 V clamp, 252.7 A pulse, 12000 W, bidirectional.
    • Product Details
    • Download

    Eaton 12KP28CAH Transient Voltage Suppressor 28 V

    12KP28CAH at a glance: transient voltage suppressor diode, 28 V standoff, 47.5 V clamp, 252.7 A pulse, 12000 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number12KP28CAH
    Standoff voltage (VR)28 V
    Leakage current at VR5 uA
    Breakdown voltage at IT31.1 V to 34.4 V
    Test current (IT)5 mA
    Clamping voltage at IPP47.5 V
    Peak pulse current252.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us12000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1058

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1058; the package line above is the
    body the part is built in.

    The Figures Explained

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.61 percent, from 31.1 V to 34.4 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 28 V standing the leakage is at most 5 uA, so the part draws 0.14 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 12KPE family this is item 5 of 14 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.