| Parameter | Value |
|---|---|
| Orderable part number | 12KP30CAH |
| Standoff voltage (VR) | 30 V |
| Leakage current at VR | 5 uA |
| Breakdown voltage at IT | 33.3 V to 36.8 V |
| Test current (IT) | 5 mA |
| Clamping voltage at IPP | 50.7 V |
| Peak pulse current | 236.7 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 12000 W |
| Package | P600 axial |
| Mounting | Through-hole |
| Operating temperature | -55 °C to +175 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1058 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data ELX1058; the package line above is the
body the part is built in.
The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.
The breakdown window spans 10.51 percent, from 33.3 V to 36.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 30 V standing the leakage is at most 5 uA, so the part draws 0.15 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 12KPE family this is item 6 of 14 in the Eaton catalogue.
Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.