Eaton 12KP40AH Unidirectional TVS Diode P600 axial
Eaton 12KP40AH Unidirectional TVS Diode P600 axial

Eaton 12KP40AH Unidirectional TVS Diode P600 axial

Share
12KP40AH: transient voltage suppressor diode, 40 V standoff, 65.8 V clamp, 182.4 A pulse, 12000 W, unidirectional.
    • Product Details
    • Download

    Eaton 12KP40AH Unidirectional TVS Diode P600 axial

    12KP40AH at a glance: transient voltage suppressor diode, 40 V standoff, 65.8 V clamp, 182.4 A pulse, 12000 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part number12KP40AH
    Standoff voltage (VR)40 V
    Leakage current at VR5 uA
    Breakdown voltage at IT44.4 V to 49.1 V
    Test current (IT)5 mA
    Clamping voltage at IPP65.8 V
    Peak pulse current182.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us12000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1058

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1058; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.59 percent, from 44.4 V to 49.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 40 V standing the leakage is at most 5 uA, so the part draws 0.2 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 12KPE family this is item 9 of 14 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products