Eaton 12KP43AH 43 V 12000 W TVS Diode
Eaton 12KP43AH 43 V 12000 W TVS Diode

Eaton 12KP43AH 43 V 12000 W TVS Diode

Share
12KP43AH: transient voltage suppressor diode, 43 V standoff, 69.8 V clamp, 171.9 A pulse, 12000 W, unidirectional.
    • Product Details
    • Download

    Eaton 12KP43AH 43 V 12000 W TVS Diode

    12KP43AH at a glance: transient voltage suppressor diode, 43 V standoff, 69.8 V clamp, 171.9 A pulse, 12000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number12KP43AH
    Standoff voltage (VR)43 V
    Leakage current at VR5 uA
    Breakdown voltage at IT47.8 V to 52.8 V
    Test current (IT)5 mA
    Clamping voltage at IPP69.8 V
    Peak pulse current171.9 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us12000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1058

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1058; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.46 percent, from 47.8 V to 52.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 43 V standing the leakage is at most 5 uA, so the part draws 0.215 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 12KPE family this is item 10 of 14 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message