Eaton 12KP48CAH Transient Voltage Suppressor 48 V
Eaton 12KP48CAH Transient Voltage Suppressor 48 V

Eaton 12KP48CAH Transient Voltage Suppressor 48 V

Share
12KP48CAH: transient voltage suppressor diode, 48 V standoff, 77.7 V clamp, 154.5 A pulse, 12000 W, bidirectional.
    • Product Details
    • Download

    Eaton 12KP48CAH Transient Voltage Suppressor 48 V

    12KP48CAH at a glance: transient voltage suppressor diode, 48 V standoff, 77.7 V clamp, 154.5 A pulse, 12000 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part number12KP48CAH
    Standoff voltage (VR)48 V
    Leakage current at VR5 uA
    Breakdown voltage at IT53.6 V to 58.7 V
    Test current (IT)5 mA
    Clamping voltage at IPP77.7 V
    Peak pulse current154.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us12000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1058

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1058; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 9.515 percent, from 53.6 V to 58.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 48 V standing the leakage is at most 5 uA, so the part draws 0.24 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 12KPE family this is item 11 of 14 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products