Eaton 12KP64AH Unidirectional TVS Diode P600 axial
Eaton 12KP64AH Unidirectional TVS Diode P600 axial

Eaton 12KP64AH Unidirectional TVS Diode P600 axial

Share
12KP64AH: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 116.5 A pulse, 12000 W, unidirectional.
    • Product Details
    • Download

    Eaton 12KP64AH Unidirectional TVS Diode P600 axial

    12KP64AH at a glance: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 116.5 A pulse, 12000 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part number12KP64AH
    Standoff voltage (VR)64 V
    Leakage current at VR5 uA
    Breakdown voltage at IT71.1 V to 78.6 V
    Test current (IT)5 mA
    Clamping voltage at IPP103 V
    Peak pulse current116.5 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us12000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1058

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1058; the package line above is the
    body the part is built in.

    The Figures Explained

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.55 percent, from 71.1 V to 78.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 64 V standing the leakage is at most 5 uA, so the part draws 0.32 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 12KPE family this is item 13 of 14 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.