Eaton 12KP72AH 72 V 12000 W TVS Diode
Eaton 12KP72AH 72 V 12000 W TVS Diode

Eaton 12KP72AH 72 V 12000 W TVS Diode

Share
12KP72AH: transient voltage suppressor diode, 72 V standoff, 116 V clamp, 103.4 A pulse, 12000 W, unidirectional.
    • Product Details
    • Download

    Eaton 12KP72AH 72 V 12000 W TVS Diode

    12KP72AH at a glance: transient voltage suppressor diode, 72 V standoff, 116 V clamp, 103.4 A pulse, 12000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number12KP72AH
    Standoff voltage (VR)72 V
    Leakage current at VR5 uA
    Breakdown voltage at IT80 V to 88.5 V
    Test current (IT)5 mA
    Clamping voltage at IPP116 V
    Peak pulse current103.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us12000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1058

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1058; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.62 percent, from 80 V to 88.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 72 V standing the leakage is at most 5 uA, so the part draws 0.36 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 12KPE family this is item 14 of 14 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.