Eaton 15BJ100CA TVS Diode, 162 V Clamp
Eaton 15BJ100CA TVS Diode, 162 V Clamp

Eaton 15BJ100CA TVS Diode, 162 V Clamp

Share
15BJ100CA: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 9.3 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ100CA TVS Diode, 162 V Clamp

    15BJ100CA at a glance: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 9.3 A pulse, 1500 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15BJ100CA
    Standoff voltage (VR)100 V
    Leakage current at VR1 uA
    Breakdown voltage at IT111 V to 123 V
    Test current (IT)1 mA
    Clamping voltage at IPP162 V
    Peak pulse current9.3 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.81 percent, from 111 V to 123 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 100 V standing the leakage is at most 1 uA, so the part draws 0.1 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 66 of 92 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd