Eaton 15BJ110CA Transient Voltage Suppressor 110 V
Eaton 15BJ110CA Transient Voltage Suppressor 110 V

Eaton 15BJ110CA Transient Voltage Suppressor 110 V

Share
15BJ110CA: transient voltage suppressor diode, 110 V standoff, 177 V clamp, 8.5 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ110CA Transient Voltage Suppressor 110 V

    15BJ110CA at a glance: transient voltage suppressor diode, 110 V standoff, 177 V clamp, 8.5 A pulse, 1500 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number15BJ110CA
    Standoff voltage (VR)110 V
    Leakage current at VR1 uA
    Breakdown voltage at IT122 V to 135 V
    Test current (IT)1 mA
    Clamping voltage at IPP177 V
    Peak pulse current8.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.66 percent, from 122 V to 135 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 110 V standing the leakage is at most 1 uA, so the part draws 0.11 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 68 of 92 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd