Eaton 15BJ12AH 12 V 1500 W TVS Diode
Eaton 15BJ12AH 12 V 1500 W TVS Diode

Eaton 15BJ12AH 12 V 1500 W TVS Diode

Share
15BJ12AH: transient voltage suppressor diode, 12 V standoff, 19.9 V clamp, 75.4 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton 15BJ12AH 12 V 1500 W TVS Diode

    15BJ12AH at a glance: transient voltage suppressor diode, 12 V standoff, 19.9 V clamp, 75.4 A pulse, 1500 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part number15BJ12AH
    Standoff voltage (VR)12 V
    Leakage current at VR1 uA
    Breakdown voltage at IT13.3 V to 14.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP19.9 V
    Peak pulse current75.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1059

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1059; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.53 percent, from 13.3 V to 14.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 12 V standing the leakage is at most 1 uA, so the part draws 0.012 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 14 of 92 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd