Eaton 15BJ130AH 130 V 1500 W TVS Diode
Eaton 15BJ130AH 130 V 1500 W TVS Diode

Eaton 15BJ130AH 130 V 1500 W TVS Diode

Share
15BJ130AH: transient voltage suppressor diode, 130 V standoff, 209 V clamp, 7.2 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton 15BJ130AH 130 V 1500 W TVS Diode

    15BJ130AH at a glance: transient voltage suppressor diode, 130 V standoff, 209 V clamp, 7.2 A pulse, 1500 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part number15BJ130AH
    Standoff voltage (VR)130 V
    Leakage current at VR1 uA
    Breakdown voltage at IT144 V to 159 V
    Test current (IT)1 mA
    Clamping voltage at IPP209 V
    Peak pulse current7.2 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1059

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1059; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.42 percent, from 144 V to 159 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 130 V standing the leakage is at most 1 uA, so the part draws 0.13 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 73 of 92 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd