| Parameter | Value |
|---|---|
| Orderable part number | 15BJ15CAH |
| Standoff voltage (VR) | 15 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 16.7 V to 18.5 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 24.4 V |
| Peak pulse current | 61.5 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 1500 W |
| Package | SMB (DO-214AA) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1059 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data ELX1059; the package line above is the
body the part is built in.
A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.
The breakdown window spans 10.78 percent, from 16.7 V to 18.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 15 V standing the leakage is at most 1 uA, so the part draws 0.015 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 15BJ family this is item 20 of 92 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
How much capacitance does it add?
Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.